Gree Air Conditioner E5 Error Code
Over-current protection on Gree air conditioners.
GreeAll Gree air conditioner codes
The system drew more current than allowed and shut off. GREE ties this to supply voltage, either too high or unstable and low. Storms, brownouts, and a weak supply circuit are common triggers.
Compatible models
Found across GREE's residential heat pump range. There's no published list of affected models.
Also shown as
No other codes are listed for this fault.
Difficulty
Start with the safe checks below; a worn part may need replacing.
Not sure you are reading the code right? See how to read Gree air conditioner codes.
How to fix Gree E5
Wait for stable power
If the power has been flickering, turn the system off and wait for things to settle.
Spot a pattern
After a reset, note when E5 comes back, for example only on the hottest afternoons or when another big appliance kicks on.
Clean filters and the outdoor coil
Shut off the outdoor disconnect, clear the outdoor coil, and rinse the indoor filters. Less strain on the system means less current draw.
When to call a technician
Repeated E5 needs a technician or electrician to check the supply voltage and wiring. GREE says the electrical supply has to be inspected and stabilized.
Parts linked to E5
These are the parts most often behind this code. Tap one to see what it does and the signs it is failing.
- power supply wiring
- compressor
- outdoor control board
Order parts by your full model number so they fit.
Frequently asked questions
Which Gree models show the E5 code?
Found across GREE's residential heat pump range. There's no published list of affected models.
Can I fix Gree E5 myself?
Often. The first steps above are safe checks a homeowner can do. If they don't clear E5, the cause is likely a worn part that needs replacing.
Other Gree air conditioner codes
- E6Indoor and outdoor units can't communicate
- E1High pressure protection
- E3Low pressure protection
- E2Indoor coil freeze protection
- E7Mode conflict between indoor units
- E8High temperature protection from low indoor airflow
- E9Condensate overflow protection
- H6Indoor fan airflow fault
- L3Outdoor fan airflow fault
- F1Indoor room temperature sensor fault
- F2Indoor coil sensor fault
- F3Outdoor air temperature sensor fault
- F4Outdoor coil sensor fault
- F5Compressor discharge sensor fault
- H1Defrosting (normal in heat mode)
- H5Power module (IPM) protection
- C5Jumper cap missing or wrong
Last reviewed 2026-10-19. Codes and steps can vary by model; check your owner's manual.