Carrier Air Conditioner Solid / 1 / 2 Error Code
Status light showing normal operation on Carrier air conditioners.
CarrierAll Carrier air conditioner codes
A steady amber light with no blinking means the outdoor unit is powered and waiting for a call. One short blink, a pause and a repeat means it's running on low stage; two blinks means high stage. None of these is a fault.
Compatible models
Shown on the amber STATUS light of Infinity two-stage outdoor units (the 24ANB7 air conditioner and the 25HNB6 and 25HNB9 heat pumps), per Carrier's installation instructions.
Also shown as
Codes 5 and 6 are settings too: they show whether the board's brown-out protection is on or off. The heat pump instructions also list codes 3 and 4, which show the outdoor fan delay setting.
Difficulty
Most people can clear this one at home with simple checks.
Not sure you are reading the code right? See how to read Carrier air conditioner codes.
How to fix Carrier Solid / 1 / 2
Compare the light with what the house is doing
If the light shows 1 or 2 and the house isn't cooling or heating, the problem sits elsewhere, often a dirty filter or a thermostat setting. Check the mode and setpoint first.
Give high stage time to kick in
On non-communicating systems, Carrier thermostats hold the unit on low stage for 15 minutes before allowing high stage, unless the room is 5°F (2.8°C) or more off the setpoint. A long run on low stage on a mild day is normal.
When to call a technician
Book a service visit if the light shows normal operation but the system can't keep up with clean filters and correct thermostat settings.
Frequently asked questions
Which Carrier models show the Solid / 1 / 2 code?
Shown on the amber STATUS light of Infinity two-stage outdoor units (the 24ANB7 air conditioner and the 25HNB6 and 25HNB9 heat pumps), per Carrier's installation instructions.
Can I fix Carrier Solid / 1 / 2 myself?
Usually, yes. Most Solid / 1 / 2 problems clear with simple checks you can do at home. Start with the first step above: compare the light with what the house is doing.
Other Carrier air conditioner codes
- 16Lost communication with the Infinity control
- 25Model plug missing or wrong
- 31 / 84High-pressure switch tripped or locked out
- 32 / 83Low-pressure or discharge temperature trip
- 45Outdoor control board fault
- 46Brown-out: supply voltage too low
- 47No 230-volt power reaching the outdoor unit
- 53 / 55 / 56Outdoor air or coil sensor fault
- 71 / 72 / 81 / 82Compressor thermal cutout or lockout
- 73 / 74Contactor stuck closed or not closing
- E1Ductless indoor and outdoor units not talking
- ECRefrigerant leak detected
- E3 / F5Ductless fan speed out of range
- E4 / E5 / F1 / F2 / F3Ductless temperature sensor open or shorted
- F0 / P1Ductless overcurrent or voltage protection
- P3Too cold outside to heat
- P5Multi-zone mode conflict
- CL / dFFilter reminder or defrost in progress