Home › Dryers › GE › 008 / 00d / F08
GE Dryer 008 / 00d / F08 Error Code
Door switch reads as stuck closed. Here is what it means and how to clear it, easiest fix first.
The dryer expects the door switch to open each time you unload. If it sees the door as closed for 5 cycles in a row, it decides the switch may be stuck and shows this code. A failed door switch, damaged switch wiring, or less often a control board fault can cause it.
Shown as 008 or 00d on GE models with three-digit codes (such as the GFD series) and as F08 on CleanSpeak-style models. Sears PartsDirect treats 008 and 00d as the same fault, but an AppliancePartsPros article says 00d points more to the board's door-sensing circuit than to the switch itself, so a technician may need to check the control board as well.
How to fix GE 008 / 00d / F08
Open and close the door fully
Open the door all the way, then close it firmly. Repeat a few times, listening for the click of the door switch.
Check the switch area
Unplug the dryer, then look at the door switch opening on the frame for lint, a lost sock, or anything that could hold the switch in. Clear it out without poking tools inside.
Reset and run a cycle
Leave the dryer unplugged (or its breaker off) for 3 minutes, restore power, run a short cycle, and open the door at the end to see if the code clears.
When to call a technician
If the code returns, a technician needs to test the door switch and its wiring and replace the faulty part. Never tape over or bypass a door switch.
Parts that commonly cause 008 / 00d / F08
- Door switch
- Door switch wiring
- Main control board
Order parts by your exact model number so they fit.
Other GE dryer codes
- Check VentLow airflow: the vent is likely blocked
- F09 (long dry time)Loads are taking too long to dry
- 006 / F06Stuck button on the control panel
- 007 / F07Power supply wired incorrectly
- 001 / 002 / 003 / 004Temperature sensor (thermistor) fault
- tEOutlet thermistor circuit fault
- 005 / F05Main control board fault
- 009Drive motor problem
- F010 / F011Cycle started with an empty drum or dry clothes
Frequently asked questions
What does 008 / 00d / F08 mean on a GE dryer?
The dryer expects the door switch to open each time you unload. If it sees the door as closed for 5 cycles in a row, it decides the switch may be stuck and shows this code. A failed door switch, damaged switch wiring, or less often a control board fault can cause it.
Can I fix GE 008 / 00d / F08 myself?
Often. The first steps above are safe checks a homeowner can do. If they don't clear 008 / 00d / F08, the cause is likely a worn part that needs replacing.
What if 008 / 00d / F08 keeps coming back?
A code that returns after a reset and the checks above usually means a part is wearing out. Note when 008 / 00d / F08 appears (which cycle, how often) and have your model number ready; it helps a technician bring the right part on the first visit.