Flame still present after the gas shut off on Worcester Bosch boilers.
Worcester BoschAll Worcester Bosch boiler codes
After the gas valve closed, the boiler kept detecting a flame. Worcester's causes are a blocked condensate trap, a damaged electrode, a flue problem, a faulty gas valve or its lead, or the PCB.
Compatible models
In the user instructions for Greenstar CDi Classic ErP combis and HighFlow 440CDi and 550CDi ErP boilers, and the engineer's booklet for CDi Classic boilers.
Also shown as
No other codes are listed for this fault.
Difficulty
Try the basic checks, but the usual fix is a technician's job.
Not sure you are reading the code right? See how to read Worcester Bosch boiler codes.
How to fix Worcester Bosch FA
Shut the boiler down
Switch off at the fused spur. Leave the casing, the gas valve and everything inside it alone.
Don't reset it repeatedly
Write the code down for the engineer and leave the boiler off.
When to call a technician
A gas valve that may not be closing needs a Gas Safe engineer straight away. Any smell of gas: no switches, open the windows, turn off at the meter if it's safe, go outside and ring your gas emergency number.
Parts linked to FA
These are the parts an engineer usually checks for this code. They sit inside the sealed casing, so leave them to a Gas Safe registered engineer.
- Gas valve and injector
- Ignition electrode and spark generator
- Condensate pipe and trap
- Flue
- PCB (main control board)
Frequently asked questions
Which Worcester Bosch models show the FA code?
In the user instructions for Greenstar CDi Classic ErP combis and HighFlow 440CDi and 550CDi ErP boilers, and the engineer's booklet for CDi Classic boilers.
Can I fix Worcester Bosch FA myself?
Only the outside checks above. If they don't clear FA, the fix is inside the boiler and needs a Gas Safe registered engineer.
Other Worcester Bosch boiler codes
- EA / EA 227Burner didn't light (no flame detected)
- CE 207 / H07Heating system water pressure too low
- E9 / E9 224Overheat limiter tripped
- FdReset button pressed or power cut during a fault
- A1Pump has run dry
- C6Fan running too slowly
- E2Heating flow temperature sensor fault
- A7Hot water temperature sensor fault
- A8Lost contact with the controls
- F7Flame signal with the burner off
- F0Internal control fault
- b1Code plug not detected
- CCOutside weather sensor not reading
- SEAnnual service due
Last reviewed 2026-10-21. Codes and steps can vary by model; check your owner's manual.