Worcester Bosch Boiler A1 Error Code
Pump has run dry on Worcester Bosch boilers.
Worcester BoschAll Worcester Bosch boiler codes
The pump is running with too little water around it. Low system pressure is the first thing Worcester's engineer booklet lists, followed by a seized pump or a worn pump bearing. The boiler blocks itself until the power has been switched off and on again.
Compatible models
Listed in the Worcester engineer's service booklet for Greenstar CDi Classic combi, system and regular boilers. The manufacturer doesn't publish a wider model list.
Also shown as
No other codes are listed for this fault.
Difficulty
Try the basic checks, but the usual fix is a technician's job.
Not sure you are reading the code right? See how to read Worcester Bosch boiler codes.
How to fix Worcester Bosch A1
Look at the pressure gauge
Below 1 bar, top the system up through the filling link to between 1 and 1.5 bar the way your user manual shows.
Power the boiler off and on
Switch the boiler off at its fused spur, wait a minute and switch it back on. A1 is a blocking fault on CDi models, so a power cycle is what clears it once the pressure is right.
When to call a technician
If the pressure is fine and A1 comes back, the pump needs checking or replacing, and the air may need purging from inside the boiler. Both are Gas Safe engineer jobs.
Parts linked to A1
These are the parts an engineer usually checks for this code. They sit inside the sealed casing, so leave them to a Gas Safe registered engineer.
Frequently asked questions
Which Worcester Bosch models show the A1 code?
Listed in the Worcester engineer's service booklet for Greenstar CDi Classic combi, system and regular boilers. The manufacturer doesn't publish a wider model list.
Can I fix Worcester Bosch A1 myself?
Only the outside checks above. If they don't clear A1, the fix is inside the boiler and needs a Gas Safe registered engineer.
Other Worcester Bosch boiler codes
- EA / EA 227Burner didn't light (no flame detected)
- CE 207 / H07Heating system water pressure too low
- E9 / E9 224Overheat limiter tripped
- FdReset button pressed or power cut during a fault
- C6Fan running too slowly
- E2Heating flow temperature sensor fault
- A7Hot water temperature sensor fault
- A8Lost contact with the controls
- F7Flame signal with the burner off
- FAFlame still present after the gas shut off
- F0Internal control fault
- b1Code plug not detected
- CCOutside weather sensor not reading
- SEAnnual service due
Last reviewed 2026-10-21. Codes and steps can vary by model; check your owner's manual.