Worcester Bosch Boiler CE 207 / H07 Error Code
Heating system water pressure too low on Worcester Bosch boilers.
Worcester BoschAll Worcester Bosch boiler codes
There isn't enough water pressure in the sealed heating circuit for the boiler to run. Pressure usually drops after radiators have been bled, through a small leak on a valve or joint, or when the relief valve has discharged. On Greenstar models Worcester asks you to recharge once the gauge falls below 1 bar (0.8 bar on the Greenstar 2000).
Compatible models
The code itself appears only in Worcester's operating instructions for GB162 V2 commercial boilers (GB162-50 to GB162-100 V2). Domestic Greenstar i, 2000, 8000 Life and 8000+ manuals give the low-pressure limits and top-up method without this code, so check your own manual for what your boiler displays.
Also shown as
Worcester's GB162 V2 commercial boiler manual lists both CE207 and H07 for low water pressure. Domestic Greenstar manuals describe the warning as a low reading on the gauge or display rather than a code; the Greenstar 8000 Life alternates LoPr with the reading and stops working at or below 0.2 bar.
Difficulty
Most people can clear this one at home with simple checks.
Not sure you are reading the code right? See how to read Worcester Bosch boiler codes.
How to fix Worcester Bosch CE 207 / H07
Read the gauge with the heating off
Let the system cool, then check the pressure gauge or the reading on the display. Worcester's target on the Greenstar i is between 1 and 1.5 bar when cold.
Top up through your filling link
Use whichever filling method your boiler has, exactly as the user manual shows. With a keyless filling link you pull the blue lever down and let go at 1 to 1.5 bar. A keyed link needs the filling key turned first, then you open the white knob and close it again at the right reading. An external filling loop has a hose and two valves that you open a quarter turn, close at 1 to 1.5 bar, and then disconnect before refitting the caps.
Let some out if you overshoot
Gone past 1.5 bar? Bleed one radiator with a radiator key until the gauge falls back into the 1 to 1.5 bar band.
Reset and keep an eye on it
Press reset if the boiler hasn't restarted on its own, then check the gauge every day or two. Look for damp under radiator valves and around visible pipework.
When to call a technician
Having to top up again and again usually means a leak or corrosion somewhere in the system, according to Worcester's Greenstar 8000+ manual. Ask your installer or a Gas Safe engineer to track it down rather than keep refilling.
Parts linked to CE 207 / H07
These are the parts an engineer usually checks for this code. They sit inside the sealed casing, so leave them to a Gas Safe registered engineer.
Frequently asked questions
Which Worcester Bosch models show the CE 207 / H07 code?
The code itself appears only in Worcester's operating instructions for GB162 V2 commercial boilers (GB162-50 to GB162-100 V2). Domestic Greenstar i, 2000, 8000 Life and 8000+ manuals give the low-pressure limits and top-up method without this code, so check your own manual for what your boiler displays.
Can I fix Worcester Bosch CE 207 / H07 myself?
Usually, yes. Most CE 207 / H07 problems clear with simple checks you can do at home. Start with the first step above: read the gauge with the heating off.
Other Worcester Bosch boiler codes
- EA / EA 227Burner didn't light (no flame detected)
- E9 / E9 224Overheat limiter tripped
- FdReset button pressed or power cut during a fault
- A1Pump has run dry
- C6Fan running too slowly
- E2Heating flow temperature sensor fault
- A7Hot water temperature sensor fault
- A8Lost contact with the controls
- F7Flame signal with the burner off
- FAFlame still present after the gas shut off
- F0Internal control fault
- b1Code plug not detected
- CCOutside weather sensor not reading
- SEAnnual service due