Mitsubishi Electric Air Conditioner U2 Error Code
Discharge temperature too high or low refrigerant. Here is what it means and how to clear it, easiest fix first.
The refrigerant leaving the compressor is running abnormally hot. Mitsubishi Electric links this to a protection device tripping or the system being short of refrigerant.
U2 meanings can vary slightly by outdoor unit series; check your manual.
How to fix Mitsubishi Electric U2
Clear the outdoor unit
Switch off the breaker. Move anything stored next to the outdoor unit and gently brush leaves and dust off the coil with a soft brush, without bending the fins. Poor airflow won't explain every U2, but it is the one cause you can rule out yourself.
Reset the power at the breaker
Switch off the breaker that feeds the air conditioner (some systems have separate breakers for the indoor and outdoor units, so switch off both). Wait about five minutes, switch the power back on and restart the unit to see if the code clears.
Stop if the code comes straight back
If U2 reappears after the reset, switch the system off and leave it off rather than restarting it again and again. Repeated restarts against a protection fault can strain the compressor and other outdoor parts.
When to call a technician
Low refrigerant means a leak that a licensed technician must find and repair. Don't open the refrigerant lines or add refrigerant yourself.
Parts that commonly cause U2
- refrigerant charge
- discharge thermistor
- compressor
Order parts by your exact model number so they fit.
Other Mitsubishi Electric air conditioner codes
- Blinking OPERATION lightWall unit's indicator light is flashing
- P1Room air temperature sensor fault
- P2 / P9Indoor coil temperature sensor fault
- P4 / P5Drain sensor or drain pump problem
- PAShut down to prevent a water leak
- P6Freeze or overheat protection
- P8Pipe temperature error
- PbIndoor fan motor error
- FbIndoor control board error
- E0-E5Wall controller communication error
- E6 / E7 / E9Indoor and outdoor units aren't communicating
- U1 / UdHigh pressure or overheat protection
- U3 / U4Outdoor temperature sensor fault
- U6 / UP / UFCompressor overcurrent
- U8Outdoor fan stopped
- U9 / UHPower supply or current sensor problem
- PLRefrigerant circuit abnormal
Frequently asked questions
What does U2 mean on a Mitsubishi Electric air conditioner?
The refrigerant leaving the compressor is running abnormally hot. Mitsubishi Electric links this to a protection device tripping or the system being short of refrigerant.
Can I fix Mitsubishi Electric U2 myself?
Only the basic checks. You can safely try the steps above, but U2 usually points to a part or fault that needs a technician.
What if U2 keeps coming back?
A code that returns after a reset and the checks above usually means a part is wearing out. Note when U2 appears (which cycle, how often) and have your model number ready; it helps a technician bring the right part on the first visit.
Last reviewed 2026-10-19. Codes and steps can vary by model; check your owner's manual.